dc.contributor.author | Aviles, P | |
dc.contributor.author | Gamboa-deBuen, I | |
dc.contributor.author | Buenfil, AE | |
dc.contributor.author | Ruiz, C | |
dc.contributor.author | Brandan, ME | |
dc.contributor.author | Rodríguez-Villafuerte, M | |
dc.contributor.author | López, K | |
dc.date.accessioned | 2011-01-22T10:28:17Z | |
dc.date.available | 2011-01-22T10:28:17Z | |
dc.date.issued | 1998 | |
dc.identifier.issn | 0094-243X | |
dc.identifier.uri | http://hdl.handle.net/11154/2701 | |
dc.description.abstract | The fluence response curve of LiF:Mg,Ti (TLD-100) exposed to 0.7, 1.5 and 3 MeV proton beams has been measured. In all cases, the total TL signal and glow curve peaks 5 to 9 show a linear-supralinear response for fluences between 10(7) and 10(12) protons/cm(2). The supralinearity increases with the energy of the incident beam. The measured relative efficiencies for protons with respect to Co-60 gamma-rays, for the total TL signal and peaks 5 and 7 indicate that the efficiency increases with energy, that is, decreases with the linear energy transfer. The efficiencies are lower than unity for the total TL signal and peak 5 and greater than unity for peak 7. | en_US |
dc.language.iso | en | en_US |
dc.title | Thermoluminescent response of TLD-100 exposed to low energy protons | en_US |
dc.type | Article | en_US |
dc.identifier.idprometeo | 2758 | |
dc.source.novolpages | 440:15-23 | |
dc.subject.wos | Physics, Applied | |
dc.subject.wos | Physics, Multidisciplinary | |
dc.description.index | WoS: SCI, SSCI o AHCI | |
dc.relation.journal | Medical Physics |
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |