Ciencias,UNAM

Frozen Solutions of Fricke Dosimeter

DSpace/Manakin Repository

Show simple item record

dc.contributor.author Ramos, A
dc.contributor.author Ramos-Bernal, S
dc.contributor.author Frias, D
dc.contributor.author Mosqueira, FG
dc.contributor.author Negron-Mendoza, A
dc.date.accessioned 2011-01-22T10:25:51Z
dc.date.available 2011-01-22T10:25:51Z
dc.date.issued 2008
dc.identifier.issn 0022-3131
dc.identifier.uri http://hdl.handle.net/11154/907
dc.description.abstract Commercial product irradiation using ionizing radiation has provided a method to safely treat products in a variety of ways. Temperature is a very important factor when determining the absorbed dose of the product. However, most irradiation complexes apply dosimetric knowledge and calculations in a temperature range above water-freeze temperature to products that Could be at a much lower temperature. This could lead to systematic errors in the irradiation procedures and to health issues. In this paper, we study the response of the Fricke dosimeter as a function of the irradiation temperature. The temperatures studied were: 77 K (liquid nitrogen), 198 K (dry ice as powder), 263 K, 298 K (room temperature), 306 K and 328 K. The results obtained show that the change in valence of iron (11) as a function of the dose was linear for frozen solutions. There is a change of the slope in the doses-response curve that shows the effect of the irradiation temperature. This suggests that a temperature correction should be considered for low-temperature irradiation. This led to the conclusion that the Fricke dosimeter can be used as a dosimeter for low-temperature, and up to 600 Gy. An attempt has been made to theoretically model the chemical response of the Fricke dosimeter and results agreed with the experimental values fairly well. en_US
dc.language.iso en en_US
dc.title Frozen Solutions of Fricke Dosimeter en_US
dc.type Article en_US
dc.identifier.idprometeo 512
dc.source.novolpages :290-293
dc.subject.wos Nuclear Science & Technology
dc.description.index WoS: SCI, SSCI o AHCI
dc.subject.keywords Fricke dosimetry
dc.subject.keywords iron salts
dc.subject.keywords low temperature
dc.subject.keywords gamma irradiation
dc.subject.keywords ferric sulfate
dc.subject.keywords frozen solution doimetry
dc.relation.journal Journal of Nuclear Science and Technology

Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account